6 - 28
6.4 Part Names and Functions
6.4.1 Part names and functions of the Q12DCCPU-V
6
PREPARATORY PROCEDURES AND SETTING
(2) 7-segment LED specifications
* 1 The LED cannot be controlled when:
A system watchdog timer error has occurred.
A user watchdog timer error has occurred.
A built-in ROM data error has been detected.
A standard RAM data error has been detected.
* 2 The LED is flashing when a standard RAM data error detected.
* 3 The LED is flashing when a battery-backed-up RAM data error detected.
Figure 6.22 7-segment LED
Table 6.8 7-segment LED specifications
Name LED status Description
7-segment LED
7-segment LED display
This LED display can be controlled with the QBF_Control7SegLED
function in user programs.
*1
It indicates the execution mode of the hardware self-diagnostics test or
initialization setting when switch operation is performed.
Flashing
A built-in ROM data error detected.
An error was detected in the built-in ROM data during startup of the C
Controller module.
The built-in ROM data are corrupt.
The C Controller module cannot be started.
Flashing
*2
Flashing
*3
A standard RAM data or a battery-backed-up RAM data error detected.
An error was detected in the standard RAM data or
a battery-backed-
up RAM data during startup of the C Controller module.
The standard RAM data or
a battery-backed-up RAM data are corrupt.
The C Controller module cannot be started.

Table of Contents