6
PREPARATORY PROCEDURES AND SETTING
6.6 Network Settings for 1:1 Connection
6 - 39
1
OVERVIEW
2
SYSTEM
CONFIGURATION
3
SPECIFICATIONS
4
FUNCTIONS
5
ACCESS VIA NETWORK
MODULES
6
PREPARATORY
PROCEDURES AND
SETTING
7
I/O NUMBER
ASSIGNMENT
8
MEMORIES AND FILES
6.6 Network Settings for 1:1 Connection
When connecting a development environment (personal computer) to a C Controller
module, connect them on one-to-one (1:1) basis by using an Ethernet cable.
*1
* 1 For the Q12DCCPU-V, use an Ethernet cable (straight cable or crossing cable).
For the Q06CCPU-V(-B), use an Ethernet cable (crossing cable).
After connection with an Ethernet cable, configure the settings of the C Controller module
from C Controller setting utility on the development environment (personal computer).
This section describes the network settings on the personal computer for 1:1 connection
between the C Controller module (CH1) and the development environment (personal
computer).
(1) System configuration for 1:1 connection
(2) Network settings for the development environment (personal computer)
(a) Network settings for the development environment (personal computer)
Set the same network address as that of the C Controller module.
Figure 6.31 System configuration for 1:1 connection
Figure 6.32 Network settings for the development environment (personal computer)
Q12DCCPU-V
Q06CCPU-V
Q06CCPU-V-B
C Controller module
Ethernet cable
Development environment
(personal computer)
C Controller module
IP address
CH1
Subnet mask
Network part
Host part
Network part Host part
Set the same value.
Set different values.
192.168.3. 3
0
1
0
255.255.255.
192.168.3.
255.255.255.
Development environment
(personal computer)