(b) GX Works2/GX Developer and SW3PVC-CCPU
In troubleshooting according to the MELSECNET/H module manual, actions to be
taken with GX Works2/GX Developer are as follows.
Table 6.3 GX Works2/GX Developer and SW3PVC-CCPU
GX Works2/GX Developer SW3PVC-CCPU
PLC diagnostics
Use the System information screen of C Controller setting
utility.
Sequence program check Check the user program for error.
Network parameter Use the Parameter settings tab of MELSECNET/H utility.
Network diagnostics
Host information
Use the Detailed module information screen of MELSECNET/
H utility.
Other station information Use the Other station monitoring tab of MELSECNET/H utility.
Network Monitor Details
Use the Detailed module information screen of MELSECNET/
H utility.
Error history monitor Use the Error history monitoring tab of MELSECNET/H utility.
Loop test
Perform a test from GX Works2/GX Developer connected to a
programmable controller CPU on another station.
Setup confirmation test
Perform a test from GX Works2/GX Developer connected to a
programmable controller CPU on another station.
Station order check test
Perform a test from GX Works2/GX Developer connected to a
programmable controller CPU on another station.
Communication test
Perform a test from GX Works2/GX Developer connected to a
programmable controller CPU on another station.
Network test
Perform a test from GX Works2/GX Developer connected to a
programmable controller CPU on another station.
Network range assignment,
common parameters, station
inherent parameters
Use the Parameter settings tab of MELSECNET/H utility.
Module's Detailed Information
screen
Use the Module information tab of MELSECNET/H utility for
the latest error code.
For error codes other than the latest one, use the Module
monitoring tab of C Controller setting utility.
Turning on/off a link device by
testing from GX Works2/GX
Developer
Use Device monitoring utility.
Routing parameters
Use the Routing parameter settings screen of MELSECNET/H
utility.
Test between station Use the Parameter settings tab of MELSECNET/H utility.
Forward loop test/Reverse loop test Use the Parameter settings tab of MELSECNET/H utility.