SPECIFICATIONS
3.2 Performance Specifications
3 - 3
1
OVERVIEW
2
SYSTEM
CONFIGURATION
3
SPECIFICATIONS
4
FUNCTIONS
5
ACCESS VIA NETWORK
MODULES
6
PREPARATORY
PROCEDURES AND
SETTING
7
I/O NUMBER
ASSIGNMENT
8
MEMORIES AND FILES
* 1 The number of bytes for the following C Controller modules is 128K bytes.
•Q12DCCPU-V with a serial number whose first five digits are "12041" or earlier
* 2 For the development environment (personal computer), refer to the following manual.
C Controller Module User's Manual (Utility Operation, Programming)
* 3 The C Controller module differentiates 10BASE-T and 100BASE-TX according to the target device.
* 4 This number applies when a repeater hub is used.
When using a switching hub, check the number of cascaded stages with the manufacturer of the
hub to be used.
Table 3.2 Performance specifications (continued)
Item
Specifications
Q12DCCPU-V Q06CCPU-V Q06CCPU-V-B
USB
Transmission speed
12Mbps (Full Speed Mode:
FS)
Power supply Self-Powered
Connector
USB series
mini-B connector
(Compliant with Universal
Serial Bus Specification)
Other electric characteristics
Compliant with USB
Specification Revision 2.0
Use of a hub is not allowed.
CompactFlash card
Supply power voltage
3.3V 5%
Supply power capacity Up to 150mA
Card size
TYPE I card
TYPE II card is not allowed.
I/O cards, such as a modem card are not allowed.
Number of loadable cards 1
Number of I/O points (number of points
accessible to actual I/O modules)
4096 points (X/Y 0 to FFF)
Clock function Year, month, day, hour, minute, second, day of week (automatic leap year detection)
Clock accuracy during power ON
Accuracy of VxWorks POSIX Clock
Accuracy may vary by the operation program.
(
Page 4-31, Section 4.7 (5) (a))
Clock accuracy during power OFF
Daily error -10.89 to +8.64 seconds (0 to 55 )
Daily error -4.32 to +5.25 seconds (25 )
Before applying power, an additional error of -0.5 to +0.5 seconds may occur.
Allowable momentary power failure time Depends on the power supply module
5V DC internal current consumption 0.97A 0.75A 0.71A
External dimensions
98 (3.86 in.) (H)
27.4 (1.08 in.) (W)
115 (4.53 in.) (D)[mm]
98 (3.86 in.) (H)
27.4 (1.08 in.) (W)
89.3 (3.52 in.) (D)[mm]
Weight 0.24kg 0.17kg