139
F3SG-SR
User’s Manual
Chapter3 Backup/Restoration
Setting with Intelligent Tap
E
Follow the flowchart below to perform the Restoration.
Yes No
No
Yes
Yes
Yes
No
No
(1)
(2)
No
Yes
If the sensor configuration of
other than the number of
beams is not the same,
perform the Backup of the
connected F3SG-SR and
then perform the Restoration
again.
Press and hold
Push Switch for
over 1 sec
Actual sensor configuration
corresponds with that in
Intelligent Tap?
Only # of beams unmatched,
other configuration
information matched
Power ON
Intelligent Tap OUT indicator
blinks
Perform Restoration
(copying settings from
Intelligent Tap to F3SG-SR)
Restoration
successful?
Turn OFF power and disconnect
Intelligent Tap from F3SG-SR
End
Intelligent Tap OUT indicator
blinks fast
Intelligent Tap OUT indicator
blinks fast and ERR indicator
lights up
Intelligent Tap IN indicator
blinks fast, OUT indicator
blinks fast, and ERR
indicator lights up
All F3SG-SR indicators other thanABI or
TOP/BTM indicator blink sequentially.
Restoration
Power OFF
Activate settings by
DIP Switch on
Intelligent Tap?
Set DIP Switch Position 1on
Intelligent Tap at ON (Lock)
and Positions 2 to 8 at OFF
Connect Intelligent Tap to
F3SG-SR
Set DIP Switch Position 1 on
Intelligent Tap at ON (Lock),
Position 2 at ON (DIP Switch
Enabled) and set Positions 3 to 8
according to your application