210
Chapter4 Changing Settings with SD Manager 3
F3SG-SR
User’s Manual
Setting with SD Manager 3
If using this function together with other functions, make settings taking the condition of adjacent zones into account.
For more information on zone adjacency conditions, refer to 2-19. Setting Zone Adjacency Conditions.
When changing the settings is complete, confirm the settings and write the configuration to the F3SG-SR.
To enable the written configuration, refer to 4-2-7-3. Writing Configuration into Intelligent Tap.
When connecting the Intelligent Tap to a F3SG-SR and trying to return the F3SG-SR to [Detecting], follow step 4 of
4-1-3-2. Connection Procedure When Using USB Connector to restart the F3SG-SR and Intelligent Tap, or click the
[Monitor] button.
No. Function name Description
Initial
value
Configurable value or
numerical range
1 Muting Time
Information
Enter values of Muting-related time limits.
For the Muting time input time limit and the Muting time limit,
setting the value to zero means the time limit is infinite.
--
Standard muting T1min: Muting input time limit
(Min. value)
0.1 s 0.1 to 3.9 s (in 0.1 s
increments)
T1max: Muting input time limit
(Max. value)
4 s 0.2 to 60 s (in 0.1 s
increments)/infinite
T2: Muting time limit 60 s 1 to 600 s (in 1 s
increments)/infinite
T3: Maximum allowable
muting signal interruption
0.1 s 0.1 to 20 s (in 0.1 s
increments)
Exit-only muting T1min: Muting input time limit
(Min. value)
0.1 s 0.1 to 3.9 s (in 0.1 s
increments)
T1max: Muting input time limit
(Max. value)
4 s 0.2 to 600 s (in 0.1 s
increments)/infinite
T2: Muting time limit 60 s 1 to 600 s (in 1 s
increments)/infinite
T3: Maximum allowable
muting signal interruption
0.1 s 0.1 to 4 s (in 0.1 s
increments)
T4: Muting end waiting time 1 s 0.1 to 20 s (in 0.1 s
increments)
T5: Exit-only muting delay time
4 s 4 to 20 s (in 0.1 s
increments)
Position detection muting T1max: Muting input time limit
(Max. value)
4 s 0.2 to 60 s (in 0.1 s
increments)/infinite
T2: Muting time limit 60 s 1 to 600 s (in 1 s
increments)/infinite
T3: Maximum allowable
muting signal interruption
0.1 s 0.1 to 4 s (in 0.1 s
increments)
2 Check installation
position
Reflects the Muting Time Information settings to the timing
chart shown in the left side of the screen, and allows data entry
to the Input Information fields.
--
3 Input Information Enter information about the work-piece. - -
4 Diagnosis of
installation
condition
It is diagnosed and displayed if the setting condition is
appropriate.
--
5 Evaluate Checks if the muting with the entered settings is possible. - -
6 Installation
diagram and
Timing chart
Shows the positions and timing chart of a work-piece, the
F3SG-SR and muting sensors. You can also make settings to
the muting time information by editing the values in the timing
chart directly.
--
7 Close Finishes the setting process of muting time information, and
returns to muting setting.
--