EasyManua.ls Logo

Panasonic FP Series - Page 1267

Panasonic FP Series
1345 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Appendix Programming Information
1266
Available address area Type Memory
size
F/P IEC
Function
External input relays 2048 X0–X127F %IX0.0–
%IX127.15
Turn on or off based on external
input.
Pulse relays 1024 P0–P63F %MX11.0.0–
%MX11.63.15
Turn on for one scan only. Used
internally by the PLC program.
Special internal relays 176 R9000–R910F %MX0.900.0–
%MX0.910.15
Turn on or off based on specific
conditions. Used internally as a
flag.
Memory area [words]
Available address area Type Memory
size
F/P IEC
Function
External input relays 128 WX0–WX127 %IW0–
%IW127
Code for specifying 16 external
input points as one word (16 bits)
of data.
External output relays 128 WY0–WY127 %QW0–
%QW127
Code for specifying 16 external
output points as one word (16
bits) of data.
Internal relays 253 WR0–WR252 %MW0.0–
%MW0.252
Code for specifying 16 internal
relays as one word (16 bits) of
data.
Link relays 128 WL0–WL127 %MW7.0–
%MW7.127
Code for specifying 16 link relays
as one word (16 bits) of data.
Data registers
1)
6000 DT0–DT5999 %MW5.0–
%MW5.5999
Data memory used in a program.
Data is handled in 16-bit units
(one word).
Link registers
1)
256 LD0–LD255 %MW8.0–
%MW8.255
Data memory shared by multiple
PLCs connected using PLC link.
Data is handled in 16-bit units
(one word)..
Timer/counter set value
area
1)
1024 SV0–SV1023 %MW3.0–
%MW3.1023
Data memory for storing the set
values of timers or counters. The
values are stored by
timer/counter number.
Timer/counter elapsed
value area
1)
1024 EV0–EV1023 %MW4.0–
%MW4.1023
Data memory for storing the
elapsed values during operation
of timers or counters. The values
are stored by timer/counter
number.
12k type 14333 FL0–FL14332 %MW9.0–
%MW9.14332
File
registers
1)
3)
32k type
(expanded)
30717 FL0–FL30716 %MW9.0–
%MW9.30716
Data memory used in a program.
Data is handled in 16-bit units
(one word).
Special data registers 256 DT90000–
DT90255
%MW5.90000–
%MW5.90255
Data memory for storing settings
and error codes.
Index registers 14 I0–ID %MW6.0–
%MW6.13
Data memory used to modify
constants and memory area
addresses.
Memory area [double words]
Available address area Type Memory
size
F/P IEC
Function
External input relays
1)
64 DWX0–DWX72 %ID0–
%ID72
Code for specifying 32 external
input points as a double word (32
bits) of data.
External output relays
1)
64 DWY0–DWY72 %QD0–
%QD72
Code for specifying 32 external
output points as a double word
(32 bits) of data.

Table of Contents