EasyManua.ls Logo

Panasonic FP Series

Panasonic FP Series
1345 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Counter instructions
707
Part III FP Instructions
LD
ST
When programming with structured text, enter the following:
Counter100:=CT( Count:= Count_input ,
Reset:= Reset_input ,
Num:= 100 ,
SV:= Setvalue );
(* Num*, 100 in this example, must be a constant *)

Table of Contents

Other manuals for Panasonic FP Series

Related product manuals