High-speed counter instructions
893
Part III FP Instructions
Software reset for channel 1
Body
The reset is performed in step 1, and 0 is entered just after that in step 2 to start counting. A reset
alone does not start counting.
POU header
(FP
, FP-X,
FP0R)
All input and output variables used for programming this function have been declared in the POU
header.
Body
The reset is performed in step 1, and 0 is entered just after that in step 2 to start counting. A reset
alone does not start counting.
LD