MIBParameters
MIBParameters
TableD2:PrivateMIBParameters(Sheet1of31)
Name OID Type
Access
Description
winlink1000OduAdmProductType 1.3.6.1.4.1.4458.1000.1.1.1 DisplayString RO ODUconfigurationdescription.
winlink1000OduAdmHwRev 1.3.6.1.4.1.4458.1000.1.1.2 DisplayString RO ODUHardwareVersion.
winlink1000OduAdmSwRev 1.3.6.1.4.1.4458.1000.1.1.3 DisplayString RO ODUSoftwareVersion.
winlink1000OduAdmLinkName 1.3.6.1.4.1.4458.1000.1.1.4 DisplayString RW LinkName.Achangeiseffectiveimmediately.
winlink1000OduAdmResetCmd 1.3.6.1.4.1.4458.1000.1.1.5 Integer RW ResetCommand.Asetcommandwithavalue
of3willcauseadevicereset.HBSonly:Aset
commandwithavalueof4willcauseadevice
resetfortheentiresector.Thereadvalueis
always0.
winlink1000OduAdmAddres 1.3.6.1.4.1.4458.1000.1.1.6 IPAddress RW ODUIPaddress.Achangeiseffectiveafterreset.
Theparameteriskeptforbackward
compatibility.Usingthealternativeparameter:
winlink1000OduAdmIpParamsCnfgis
recommended.
winlink1000OduAdmMask 1.3.6.1.4.1.4458.1000.1.1.7 IPAddress RW ODUSubnetMask.Achangeiseffectiveafter
reset.Theparameteriskeptforbackward
compatibility.Usingthealternativeparameter:
winlink1000OduAdmIpParamsCnfgis
recommended.
winlink1000OduAdmGateway 1.3.6.1.4.1.4458.1000.1.1.8 IPAddress RW ODUdefaultgateway.Achangeiseffectiveafter
reset.Theparameteriskeptforbackward
compatibility.Usingthealternativeparameter:
winlink1000OduAdmIpParamsCnfgis
recommended.
winlink1000OduAdmBroadcast 1.3.6.1.4.1.4458.1000.1.1.1
0
Integer RW ThisparameterisreservedfortheManager
application providedwiththeproduct.
winlink1000OduAdmHostsTable N/A Trapdestinationstable.Eachtrapdestinationis
definedbyanIPaddressandaUDPport.Upto
10addressescanbeconfigured.
winlink1000OduAdmHostsEntry N/A Trapdestinationstableentry.INDEX{
winlink1000OduAdmHostsIndex}
winlink1000OduAdmHostsIndex RO Trapdestinationstableindex.
winlink1000OduAdmHostsIp 1.3.6.1.4.1.4458.1000.1.1.1
2.1.2
IPAddress RW TrapdestinationIPaddress.Achangeiseffective
immediately.
winlink1000OduAdmHostsPort 1.3.6.1.4.1.4458.1000.1.1.1
2.1.3
Integer RW UDPportofthetrapdestination.Achangeis
effectiveimmediately.
winlink1000OduBuzzerAdminState 1.3.6.1.4.1.4458.1000.1.1.1
3
Integer RW Thisparametercontrolstheactivationofthe
buzzerwhiletheunitisininstallmode.A
changeiseffectiveimmediately.Thevalidvalues
are:disabled(0)enabledAuto(1)
enabledConstantly(2)advancedAuto(3).
winlink1000OduProductId 1.3.6.1.4.1.4458.1000.1.1.1
4
DisplayString RO ThisparameterisreservedfortheManager
application providedwiththeproduct.
winlink1000OduReadCommunity 1.3.6.1.4.1.4458.1000.1.1.1
5
DisplayString RW ReadCommunityString.Thisparameteralways
returns*****whenretrievingitsvalue.Itis
usedbytheManagerapplicationtochangethe
ReadCommunity String.TheSNMPagent
acceptsonlyencryptedvalues.
winlink1000OduReadWriteCommu
nity
1.3.6.1.4.1.4458.1000.1.1.1
6
DisplayString RW Read/WriteCommunityString.Thisparameter
alwaysreturns*****whenretrievingitsvalue.
ItisusedbytheManagerapplicationtochange
theRead/WriteCommunityString.TheSNMP
agentacceptsonlyencryptedvalues.