MIBParameters
winlink1000OduTrapCommunity 1.3.6.1.4.1.4458.1000.1.1.1
7
DisplayString RW TrapCommunityString.Thisparameterisused
bytheManagerapplicationtochangetheTrap
CommunityString.TheSNMPagentaccepts
onlyencryptedvalues.
winlink1000OduAdmSnmpAgentVe
rsion
1.3.6.1.4.1.4458.1000.1.1.1
8
Integer RO MajorversionoftheSNMPagent.
winlink1000OduAdmRemoteSiteNa
me
1.3.6.1.4.1.4458.1000.1.1.1
9
DisplayString RO Remotesitename.Returnsthesamevalueas
sysLocationparameteroftheremotesite.
winlink1000OduAdmSnmpAgentMi
norVersion
1.3.6.1.4.1.4458.1000.1.1.2
0
Integer RO MinorversionoftheSNMPagent.
winlink1000OduAdmLinkPassword 1.3.6.1.4.1.4458.1000.1.1.2
1
DisplayString RW LinkPassword.Thisparameteralwaysreturns
*****whenretrievingitsvalue.Itisusedby
theManagerapplicationtochangetheLink
Password.TheSNMPagentacceptsonly
encryptedvalues.
winlink1000OduAdmSiteLinkPassw
ord
1.3.6.1.4.1.4458.1000.1.1.2
2
DisplayString RW SiteLinkPassword.Thisparameteralways
returns*****whenretrievingitsvalue.Itis
usedbytheManagerapplicationtochangethe
LinkPasswordofthesite.TheSNMPagent
acceptsonlyencryptedvalues.
winlink1000OduAdmDefaultPasswo
rd
1.3.6.1.4.1.4458.1000.1.1.2
3
Integer RO ThisparameterindicatesifthecurrentLink
Passwordisthedefaultpassword.
winlink1000OduAdmConnectionTy
pe
1.3.6.1.4.1.4458.1000.1.1.2
4
Integer RO ThisparameterindicatesiftheManager
application isconnectedtothelocalODUorto
theremoteODUovertheair.Avalueof
'unknown'indicatescommunitystring
mismatch.
winlink1000OduAdmBackToFactory
SettingsCmd
1.3.6.1.4.1.4458.1000.1.1.2
5
Integer RW BacktofactorysettingsCommand.Achangeis
effectiveafterreset.Thereadvalueisalways
0.
winlink1000OduAdmIpParamsCnfg 1.3.6.1.4.1.4458.1000.1.1.2
6
DisplayString RW ODUIPaddressConfiguration.Theformatis:
<IP_Address>|<Subnet_Mask>|<Default_Gatew
ay>|
winlink1000OduAdmVlanID 1.3.6.1.4.1.4458.1000.1.1.2
7
Integer RW VLANID.Validvaluesare1to4094.Initialvalue
is0meaningVLANunaware.
winlink1000OduAdmVlanPriority 1.3.6.1.4.1.4458.1000.1.1.2
8
Integer RW VLANPriority.0islowestpriority7ishighest
priority.
winlink1000OduAdmSN 1.3.6.1.4.1.4458.1000.1.1.2
9
DisplayString RO ODUSerialNumber
winlink1000OduAdmProductName 1.3.6.1.4.1.4458.1000.1.1.3
0
DisplayString RO ThisistheproductnameasitexistsatEC
winlink1000OduAdmActivationKey 1.3.6.1.4.1.4458.1000.1.1.3
1
DisplayString RW Activatesageneralkey.
winlink1000OduAdmRmtPermitted
OduType
1.3.6.1.4.1.4458.1000.1.1.3
2
DisplayString RW MobileApplication:permittedpartnerOduType.
winlink1000OduAdmCpuID 1.3.6.1.4.1.4458.1000.1.1.3
3
Integer RO CPUID
winlink1000OduAdmOvrdCmd RW AbilitytoperformspecialcommandintheODU.
winlink1000OduSrvMode 1.3.6.1.4.1.4458.1000.1.2.1 Integer RW Systemmode.Theonlyvaluesthatcanbeset
areinstallModeandslaveMode;normalMode
reservedtotheManagerapplicationprovided
withtheproduct.Achangeiseffectiveafter
linkresynchronization.
winlink1000OduSrvBridging 1.3.6.1.4.1.4458.1000.1.2.3 Integer RO BridgingMode.Validvaluesare:disabled(0)
enabled(1).
winlink1000OduSrvRingLinkMode 1.3.6.1.4.1.4458.1000.1.2.4.
1
Integer RW Modeofthelinkregardingringtopology.
TableD2:PrivateMIBParameters(Sheet2of31)
Name OID Type
Access
Description

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Radwin 2000 and is the answer not in the manual?

Radwin 2000 Specifications

General IconGeneral
BrandRadwin
Model2000
CategoryMicrophone system
LanguageEnglish

Related product manuals