RADWIN2000UserManual Release2.8.30 D‐41
MIBTraps
encryptionAlarm 103 major Indicatesanencryptionkey
mismatch.Containsasingle
parameterwhichisitsdescription:
1‐Description:EncryptionStatus‐
Failed.NoServicesareavailable.
changeLinkPasswordAlarm 104 major Indicatesthatafailurehasoccurred
whileattemptingtochangetheLink
Password.Containsasingle
parameterwhichisitsdescription:
1‐Description:Failedtochangethe
LinkPasswordat/on:%s.%s‐Isthe
LocalSitenameorRemoteSitename
orbothsidesoftheLink.
externalAlarmInPort1Alarm 105 major Thetrapissenteverytimeanalarm
occursintheExternalAlarmInputof
port#1.Containsasingleparameter
whichisitsdescription:1‐
Description:ExternalAlarm1‐<User
Text>‐Alarm.
externalAlarmInPort2Alarm 106 major Thetrapissenteverytimeanalarm
occursintheExternalAlarmInputof
port#2.Containsasingleparameter
whichisitsdescription:1‐
Description:ExternalAlarm2‐<User
Text>‐Alarm.
bitFailedAlarm 107 major Thetrapissentifthereisnowayto
recoverfromthesituation.Contains
twoparameters:1‐Description:
ODUpowerupbuiltintestfailed.
Errorcodeis:%n2‐%nnumber
wrongConfigurationLoadedAlarm 108 major Thetrapissentifthereisawayto
recoverfromthesituation.Contains
twoparameters:1‐Description:
Wrongconfigurationloaded.Error
codeis:%n2‐%nnumber
lanPort1DisconnectedAlarm 109 major IndicatestheLANport1status
changedtodisconnected.Containsa
singleparameterwhichisits
description:1‐Description:LAN
port1statuschangedto
disconnected.
TableD‐3:MIBTraps(Sheet5of14)
Name ID Severity Description