RADWIN2000UserManual Release2.8.30 D‐42
MIBTraps
lanPort2DisconnectedAlarm 110 major IndicatestheLANport2status
changedtodisconnected.Containsa
singleparameterwhichisits
description:1‐Description:LAN
port2statuschangedto
disconnected.
mngPortDisconnectedAlarm 111 major Indicatesthemanagementport
statuschangedto
disconnected.Containsasingle
parameterwhichisitsdescription:
1‐Description:Managementport
statuschangedtodisconnected.
externalAlarmInPort3Alarm 112 major Thetrapissenteverytimeanalarm
occursintheExternalAlarmInputof
port#3.Containsasingleparameter
whichisitsdescription:1‐
Description:ExternalAlarm3‐<User
Text>‐Alarm.
externalAlarmInPort4Alarm 113 major Thetrapissenteverytimeanalarm
occursintheExternalAlarmInputof
port#4.Containsasingleparameter
whichisitsdescription:1‐
Description:ExternalAlarm4‐<User
Text>‐Alarm.
swVersionsMismatchFullCompatibilit
yAlarm
114 warning ThetrapissentifSWversions
mismatchwithfulllinkfunctionality.
Containsasingleparameterwhichis
itsdescription:1‐Description:
Softwareversionsmismatch‐fulllink
functionality
swVersionsMismatchRe strictedComp
atibilityAlarm
115 minor ThetrapissentifSWversions
mismatchwithrestrictedlink
functionality.Containsasingle
parameterwhichisitsdescription:
1‐Description:Softwareversions
mismatch‐restrictedlink
functionality
swVersionsMismatchSoftwareUpgrad
eRequired
116 major ThetrapissentifSWversions
mismatchandSWupgradeis
required.Containsasingle
parameterwhichisitsdescription:
1‐Description:Softwareversions
mismatch‐Softwareupgrade
required
TableD‐3:MIBTraps(Sheet6of14)
Name ID Severity Description