R&S FSL WiMAX, WiBro Measurements (Options K92/K93)
1300.2519.12 2.143 E-11
In the Frequency field, enter the desired frequency to measure.
If a frequency is entered, which maps to a specific channel, the Channel No field updates.
In the Frequency Band field, select the signal to be analyzed. The target band is either one of
the bands given as example in the IEEE 802.16–2004 standard
3
or an unspecified band.
In the Channel BW or Sampling Rate field depending on the characteristics of the signal to be
analyzed, select a value. The second parameter is derived from the first according to the
standard
4
.
In the G = Tg/Tb field, select a useful time ratio according to the characteristics of the signal to
be analyzed.
Under Level Settings, deactivate the Auto Lev option. In this example, the level detection
measurement is executed manually (for details see Performing the level detection).
3. Press the Settings General/Demod softkey twice to select and open the Demod Settings dialog
box.
3 B.3.2 Wireless MAN-OFDM/OFDMA PHY symbol and performance parameters.
4 8.3.2.2 Derived Parameter definitions