R&S FSL SENSe Subsystem (Power Meter, K9)
1300.2519.12 6.383 E-11
SENSe Subsystem (Power Meter, K9)
The SENSe subsystem is organized in several subsystems. The commands of these subsystems
directly control devicespecific settings, they do not refer to the signal characteristics of the
measurement signal.
The SENSe subsystem controls the essential parameters of the analyzer. In accordance with the SCPI
standard, the keyword "SENSe" is optional for this reason, which means that it is not necessary to
include the SENSe node in command sequences.
The following subsystems are included:
"SENSe:PMETer Subsystem" on page 6.383
SENSe:PMETer Subsystem (Power Meter, K9)
This subsystem controls the device settings for power sensor measurements.
Commands of the SENSe:PMETer Subsystem
[SENSe<1|2>:]PMETer[:STATe]
[SENSe<1|2>:]PMETer:FREQuency
[SENSe<1|2>:]PMETer:FREQuency:LINK
[SENSe<1|2>:]PMETer:MTIMe
[SENSe<1|2>:]PMETer:MTIMe:AVERage[:STATe]
[SENSe<1|2>:]PMETer:MTIMe:AVERage:COUNt
[SENSe<1|2>:]PMETer:ROFFset[:STATe]
[SENSe<1|2>:]PMETer:TRIGger[:STATe]
[SENSe<1|2>:]PMETer:TRIGger:LEVel
[SENSe<1|2>:]PMETer[:STATe]
This command switches the power sensor measurements on or off.
The numeric suffixes <1|2> are irrelevant.
Parameter
ON | OFF
Example
PMET ON
Switches the power sensor measurements on.
Characteristics
*RST value: OFF
SCPI: device–specific