3GPP Base Station Measurements (Option K72)  R&S FSL  
1300.2519.12 2.108  E-11 
3GPP Base Station Measurements (Option K72) 
This section explains basic 3GPP FDD base station tests by means of a setup with a signal generator, 
e.g. an R&S SMU. It describes how operating and measurement errors can be avoided using correct 
settings. The measurements are performed with an R&S FSL equipped with the 3GPP Base Station 
Measurements option (K72).  
The following measurements are described: 
 Measuring the Signal Channel Power 
 Measuring the Spectrum Emission Mask 
 Measuring the Relative Code Domain Power 
 Synchronization of the reference frequencies 
 Behavior with deviating center frequency setting 
 Behavior with incorrect scrambling code 
 Measuring the Relative Code Domain Power 
 Trigger offset 
Furthermore, the test setup for base station tests is given: 
 Setup for Base Station Tests 
For measurements on base–station signals in line with 3GPP, test models with different channel 
configurations are specified in the document "Base Station (BS) conformance testing (FDD)" (3GPP TS 
25.141
 V7.4.0).  
For further information on measurement examples refer also to the Quick Start Guide, chapter 5 "Basic 
Measurement Examples". 
This option is available from firmware version 1.60. 
 
Measuring the Signal Channel Power 
The R&S FSL measures the unweighted RF signal power in a bandwidth of 
22.0|84.3)1(5 =+=
MHzMHzf
BW
 
The power is measured in zero span using a digital channel filter of 5 MHz in bandwidth. According to 
the 3GPP standard, the measurement bandwidth (5 MHz) is slightly larger than the minimum required 
bandwidth of 4.7 MHz.  
Test setup: 
 Connect the RF output of the signal generator to the RF input of the R&S FSL (coaxial cable with N 
connectors).  
Signal generator settings (e.g. R&S SMU): 
Frequency: 2.1175 GHz 
Level:  0 dBm 
Standard: WCDMA/3GPP 
Test model:  1, 32 DPCH channels