CONFigure Subsystem (Noise Figure, K30) R&S FSL
1300.2519.12 6.532 E-11
CONFigure Subsystem (Noise Figure, K30)
The CONFigure subsystem contains commands for configuring complex measurement tasks.
Commands of the CONFigure Subsystem
CONFigure:ARRay:MEMory<1...3>
CONFigure:CORRection
CONFigure:LIST:CONTinuous
CONFigure:LIST:SINGle
CONFigure:SINGle
CONFigure:ARRay:MEMory<1...3>
This command saves the current trace results (noise figure, noise temperature and noise gain
traces) to trace memory <n>.
This command is an event and therefore has no *RST value and no query.
This command is available from firmware version 1.60.
Parameter
ONCE
Example
INIT
Starts a new measurement, if no measurement sequence is already in progress.
CONF:ARR:MEM2 ONCE
Copies the last recorded measurement result into the memory 2.
Characteristics
RST value:
SCPI: device–specific
Mode
NF
CONFigure:CORRection
This command configures for a second stage correction measurement.
This command is an event and therefore has no *RST value and no query.
Example
CONF:CORR
Configures to run second stage correction measure measurements.
INIT
Starts a new measurement, if no measurement sequence is already in progress.
Characteristics
*RST value: –
SCPI: device–specific
Mode
NF