R&S FSL CALCulate:MARKer Subsystem (WiMAX, K92/K93)
1300.2519.12 6.775 E-11
CALCulate:MARKer Subsystem (WiMAX, K92/K93)
The CALCulate:MARKer subsystem checks the marker functions of the instrument.
N
ote: Currently there is only marker 1 available and it is always on.
The following subsystem is included:
• "CALCulate:MARKer:FUNCtion Subsystem (WiMAX, K92/K93)" on page 6.781
Commands of the CALCulate:MARKer Subsystem
– CALCulate<1|2>:MARKer<1>[:STATe]
– CALCulate<1|2>:MARKer<1>:AOFF
– CALCulate<1|2>:MARKer<1>:BURSt
– CALCulate<1|2>:MARKer<1>:CARRier
– CALCulate<1|2>:MARKer<1>:MAXimum[:PEAK]
– CALCulate<1|2>:MARKer<1>:MINimum[:PEAK]
– CALCulate<1|2>:MARKer<1>:SYMBol
– CALCulate<1|2>:MARKer<1>:TRACe
– CALCulate<1|2>:MARKer<1>:FUNCtion:TTCapture:TIME?
– CALCulate<1|2>:MARKer<1>:X
– CALCulate<1|2>:MARKer<1>:Y?
CALCulate<1|2>:MARKer<1>[:STATe]
This command switches the markers in the specified measurement window on or off.
Parameter
ON | OFF
Example
CALC1:MARK1 ON
Switches the screen A marker ON.
Characteristics
RST value: ON
SCPI: device–specific
Mode
OFDM, OFDMA/WiBro
CALCulate<1|2>:MARKer<1>:AOFF
This command switches off all active markers in the specified measurement window. The
window is set by the numeric suffix of CALCulate<1|2>.
Example
CALC1:MARK:AOFF
Switches off all markers in the screen A window.