Remote Commands of the CDMA2000 BTS Analyzer Option (K82)  R&S FSL  
1300.2519.12 6.604  E-11 
CONFigure Subsystem (CDMA, K82) 
The CONFigure subsystem contains commands for configuring the measurements.  
The following subsystem is included: 
• "CONFigure:CDPower Subsystem (CDMA, K82)" on page 6.604 
CONFigure:CDPower Subsystem (CDMA, K82) 
This subsystem contains the commands for measurement selection and configuration of the 
CDMA2000 BTS Analyzer option.  
Further setting commands for the spectrum emission mask measurement are in the 
"CALCulate:LIMit:ESPectrum Subsystem (CDMA, K82)" on page 6.599. 
Commands of the CONFigure:CDPower Subsystem 
– CONFigure:CDPower[:BTS]:CTABle[:STATe] 
– CONFigure:CDPower[:BTS]:CTABle:CATalog? 
– CONFigure:CDPower[:BTS]:CTABle:COMMent 
– CONFigure:CDPower[:BTS]:CTABle:COPY 
– CONFigure:CDPower[:BTS]:CTABle:DATA 
– CONFigure:CDPower[:BTS]:CTABle:DELete 
– CONFigure:CDPower[:BTS]:CTABle:NAME 
– CONFigure:CDPower[:BTS]:CTABle:SELect 
– CONFigure:CDPower[:BTS]:BCLass 
– CONFigure:CDPower[:BTS]:MCARier[:STATe] 
– CONFigure:CDPower[:BTS]:MEASurement 
– CONFigure:CDPower:CTABle:RESTore 
CONFigure:CDPower[:BTS]:CTABle[:STATe] 
 
This command activates or deactivates the ‘RECENT’ channel table. To select another channel 
table, use the CONFigure:CDPower[:BTS]:CTABle:SELect command. 
Parameter 
ON | OFF 
Example 
INST:SEL BC2K 
Activates the CDMA2000 BTS Analyzer option. 
INIT:CONT OFF 
Selects single sweep.  
INIT;*WAI 
Starts measurement with synchronization. 
CONF:CDP:CTAB ON 
Activates predefined channel table. 
CONF:CDP:CTAB:SEL 'CTAB_1' 
Selects channel table.