Loading...
1xEV-DO BTS Analyzer (Option K84) R&S FSL
1300.2519.12 4.382 E-11
Composite EVM
The composite EVM value is the difference between the test signal and ideal reference signal
(also see Composite EVM).
Max. Pwr DATA
Shows the maximum power of the Data channel. This is the highest value of the I- and Q-branch
of the Data channel.
Min. Pwr. DATA
Shows the minimum power of the Data channel. This is the smallest value of the I- and Q-
branch of the Data channel.
Data Mode Type
Shows the modulation type of the Data channel.
Act. MAC Chs
Shows the number of active MAC channels.
Act. DATA Chs
Shows the number of active Data channels.
Preamble Length
Shows the length of the preamble in chips. If no preamble is present in the slot, this value is 0.
RHO
Shows the quality parameter RHO calculated over a slot.
Max. inact. Pwr MAC
Shows the maximum power of inactive MAC channels. This is the highest inactive channel from
the I- and Q-branch of the MAC channels.
Remote: CALC:FEED "XTIM:CDP:ERR:SUMM"
Remote: CALC:MARK:FUNC:POW:RES?
Channel Results
Under Channel Results, the measurement results that concern a specific channel are displayed.
The upper part of the result display shows common results for the selected channel:
Power
Shows the total power of the selected channel type.
IQ Imbalance
Shows the IQ imbalance of the signal in percent.
Pk CDE (SF xx/IQ)
The Peak Code Domain Error measurement specifies a projection of the difference between test
signal and ideal reference signal to the spreading factor that belongs to the channel type. This
spreading factor is shown in brackets.
IQ Offset
Shows the DC offset of the signal in percent.
The bottom part of the result display shows results specific to the selected channel type and the
selected slot:

Table of Contents