R&S FSL WiMAX, WiBro Measurements (Options K92/K93)
1300.2519.12 4.469 E-11
SEM Settings (IEEE 802.16e–2005 WiBro)
Opens the Spectrum Emission Mask Settings dialog box to configure the Spectrum Emission
Mask measurement.
SEM according to
Specifies how the Spectrum Emission Mask settings and limits are
applied:
TTA Standard – as specified in the standard.
User – as specified in the selected XML file
File Name
Specifies the XML file name
Link Direction
Sets the link direction:
UL – uplink, DL – downlink
Power Class
Sets the power class:
Auto – automatic selection
(–INF, 23) dBm, (23, INF) dBm – power class values for uplink
(–INF, 29) dBm, (29, 40) dBm, (40, INF) dBm – power class values
for downlink
The other parameters are set by default.
The SEM Configuration shows the settings and limits applied over specified frequency ranges
around the TX channel. The settings displayed are dependent on the selected Link Direction
and Power Class.
This softkey is available from firmware version 1.60.
Remote: POW:SEM:TTA STANDARD (SEM according to)
Remote: POW:SEM:MOD UL (Link Direction)
Remote: POW:SEM:CLAS 0 (Power Class)
Import
Opens the Choose iqw file to import dialog box.
Enter the path and the name of the IQ data file you want to import. Focus the Select button and
press ENTER to load the specified IQ data file. The Select button becomes active only, if the
entered name matches a file name in the selected directory.
Remote: MMEM:LOAD:IQ:STAT 1,'C:\R_S\Instr\user\data.iqw'