R&S FSL CALCulate Subsystem
1300.2519.12 6.17 E-11
C
ALCulate<1|2>:DELTamarker<1...4>:MAXimum[:PEAK]
This command positions the delta marker to the current maximum value on the measured curve.
If necessary, the corresponding delta marker will be activated first.
For CDMA2000 and 1xEV-DO code domain measurements (option K82 and K84) the numeric
suffix <1|2> selects the measurement screen. In the other modes the numeric suffix <1|2> is
irrelevant.
This command is an event and therefore has no *RST value and no query.
Example
CALC:DELT3:MAX
Sets delta marker 3 to the maximum value of the associated trace.
Characteristics
RST value:
SCPI: device–specific
Mode
A, ADEMOD, CATV, CDMA, EVDO, SPECM, WCDMA
CALCulate<1|2>:DELTamarker<1...4>:MAXimum:LEFT
This command positions the delta marker to the next smaller maximum value to the left of the
current value (i.e. descending X values). The corresponding delta marker will be activated first,
if necessary.
For CDMA2000 and 1xEV-DO code domain measurements (option K82 and K84) the numeric
suffix <1|2> selects the measurement screen. In the other modes the numeric suffix <1|2> is
irrelevant.
This command is an event and therefore has no *RST value and no query.
Example
CALC:DELT:MAX:LEFT
Sets delta marker 1 to the next smaller maximum value to the left of the current value.
Characteristics
RST value:
SCPI: device–specific
Mode
A, ADEMOD, CATV, CDMA, EVDO, SPECM, WCDMA
CALCulate<1|2>:DELTamarker<1...4>:MAXimum:NEXT
This command positions the delta marker to the next smaller maximum value on the measured
curve. The corresponding delta marker will be activated first, if necessary.
For CDMA2000 and 1xEV-DO code domain measurements (option K82 and K84) the numeric
suffix <1|2> selects the measurement screen. In the other modes the numeric suffix <1|2> is
irrelevant.
This command is an event and therefore has no *RST value and no query.
Example
CALC:DELT2:MAX:NEXT
Sets delta marker 2 to the next smaller maximum value.