EM500 Open-Loop Vector Control Inverter User Manual
131
Options
F15.37
PWM Modulation
Method
0.00 - Maximum Frequency F00.16
Hz
15.00
●
F15.38
Deadband
Compensation Mode
0: Disabled
1: Compensation Mode 1
2: Compensation Mode 2
1
〇
F15.39
Terminal Jog
Priority
0: Disabled
1: Enabled
0
〇
F15.40
Deceleration Time
at Rapid Stop
0.00 - 650.00 (F15.13=0)
0.0 - 6500.0 (F15.13=1)
0 - 65000 (F15.13=2)
s
1.00
●
F15.41
~
F15.43
Not Used
F15.44
Phase Angle
Adjustment Enabled
0: Enbabled
1: Shut Down
0
●
F15.45
Power
frequencyVariable
frequency-Power
frequency switching
mode
0: Automatic
1: Manual
0
〇
F15.46
The Switching Time
0~1000
ms
100
〇
F15.47
Phase card startup
latency
0~1000
ms
100
〇
F15.48
Direction of the
phase Angle
0: Advanced
1: Lag
0
〇
F15.49
Phase Angle
Difference
0~180
°
0
●
F15.50
The current phase
Angle error
-180~180
°
0
●
F15.51
The phase adjusting
gain
0.00-600.00
1.00
×
F15.52
Phase-locked loop
proportional gain
0.00~600.00
0.00
●
F15.53
Phase-locked loop
integral gain
0.00~600.00
0.00
●
F15.54
Phase-locked loop
filtering time
0.00~100.00
ms
0.50
●
F16
Customized Function Group