EasyManua.ls Logo

Sinee EM500 - Motor 1 Parameter

Sinee EM500
459 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
EM500 Open-Loop Vector Control Inverter User Manual
81
F00.21
Reverse Control
0: Permit Forward/Reverse
1: Prohibit Reverse
0
F00.22
F/R Deadband Time
0.00 - 650.00
s
0.00
F00.23
Carrier Frequency
1.0 - 16.0 (inverter rated power 0,75
4.00kW)
1.0 - 10.0 (inverter rated power 5.50 -
7.50 kW)
1.0 - 8.0 (inverter rated power 11.00
45.00 kW)
1.0 - 4.0 (inverter rated power 55.00
90.00 kW)
1.0 - 3.0 (inverter rated power 110.00
560.00 kW)
kHz
4.0
(7.5kW
and the
followin
g2.0
F00.24
Automatic
Adjustment of
Carrier Wave
0: Disabled
1: Enabled 1
2: Enabled 2
1
F00.25
Carrier Frequency
Noise Suppression
0: Disabled
1: Enabled
0
F00.26
Noise Suppression
Tone
20 - 200
Hz
40
F00.27
Noise Suppression
Intensity
10 - 150
Hz
100
F00.28
Motor Parameter
Group Options
0: Motor 1 Parameter
1: Motor 2 Parameter
0
F00.29
User Password
0 - 65535
0
F00.30
Inverter Type
0: G
1: P
0
F00.31
Frequency resolution
0: 0.01Hz
1: 0.1Hz
F01
Motor 1 Parameter
F01.00
Motor Type
0: Common Induction Motor
1: Inverter Induction Motor
2: Permanent Magnet Synchronous
Motor
0
F01.01
Motor Rated Power
0.10 - 650.00
kW
Up To
Specific
Model
F01.02
Motor Rated Voltage
50 - 2000
V
Up To
Specific
Model

Table of Contents