EM500 Open-Loop Vector Control Inverter User Manual
174
0: Motor 1 Parameter
Disabled
Motor 1
F00/F01/F06
Enabled
Motor 2
F14
1: Motor 2 Parameter
Disabled
Motor 2
Enabled
Motor 1
F00/F01/F06
No.
Function
Range
Unit
Default
Type
F00.29
User Password
0 - 65535
0
F00.29 is used to set a new password to enable the password protection function and
avoid misoperation of the function codes of inverter. If the new password is 0, then the
password protection function is disabled. After setting the user password (none 0), in
addition to the function code, all the parameters can only be viewed, cannot be modified.
No.
Function
Range
Unit
Default
Type
F00.30
Inverter Type
0: G
1: P
0
F00.30=0 Set inverter as Type G, which applies to mechanical and constant torque load;
F00.30=1 Set inverter as Type P, which applies to fan, water pump and other square or
cubic load.
When inverter is set as Type P, please refer to motor nameplate for applicable motor
power. Make sure that it cannot be applied to constant torque load at this type.
7.2 F01 Group: Motor 1 Parameter
No.
Function
Range
Unit
Default
Type
F01.00
Motor Type
0: Common Induction Motor
1: Inverter Induction Motor
2: Permanent Magnet
Synchronous Motor
0
EM500 supports the induction motor and the synchronous motor. Please set this
parameter according to actual applications.
No.
Function
Range
Unit
Default
Type
F01.01
Motor Rated
Power
0.10 - 650.00
kW
Up To
Specific
Model