EM500 Open-Loop Vector Control Inverter User Manual
144
timing choice of
water supply
1: Effective on Sunday, Saturday is
invalid
2: Saturday and Sunday is invalid
F26.18
T1 Start time
00.00~23.59
0.00
〇
F26.19
Pressure at time T1
F25.03~F25.02
%
/MP
a
0.1
〇
F26.20
T2 Start time
T1~23.59
0.00
〇
F26.21
Pressure at time T2
F25.03~F25.02
%
/MP
a
0.1
〇
F26.22
T3 Start time
T2~23.59
0.00
〇
F26.23
Pressure at time T3
F25.03~F25.02
%
/MP
a
0.1
〇
F26.24
T4 Start time
T3~23.59
0.00
〇
F26.25
Pressure at time T4
F25.03~F25.02
%
/MP
a
0.1
〇
F26.26
T5 Start time
T4~23.59
0.00
〇
F26.27
Pressure at time T5
F25.03~F25.02
%
/MP
a
0.1
〇
F26.28
T6 Start time
T5~23.59
0.00
〇
F26.29
Pressure at time T6
F25.03~F25.02
%
/MP
a
0.1
〇
F27
Winding rolling application
F27.00
The application of
macro
0: Winding mode
1:Unwinding mode
2:Wire drawing mode
3:Straight wire drawing machine mode
0
〇
F27.01
Feedforward Gain
Effect channel
0: Feedforward Gain *Given source B
1: Feedforward Gain *Given source A
2: Feedforward Gain *10V
1
〇
F27.02
Feedforward Gain
input mode
0:Feedforward gain invariability
1: 0.00~Upper Limit feedforward gain
2:- Upper Limit feedforward gain~+
Upper Limit feedforward gain
1
〇
F27.03
Feedforward
Ones Place:Feedforward reset option
10
〇