EM500 Open-Loop Vector Control Inverter User Manual
145
Control
0: Automatic reset
1: Terminal reset
Tens Place:Feedforward power off and
parking choice
0: Power off saved
1: Power off unsaved
F27.04
Upper Limit
feedforward gain
0.00~500.00
%
500.00
〇
F27.05
Feedforward initial
gain
0.00~500.00
%
50.00
●
F27.06
feedforward gain
filtering time
0~1000
ms
0
●
F27.07
Feedforward range 0
0.00~ Feedforward range1
%
4.00
●
F27.08
Feedforward range 1
Feedforward range 1~ Feedforward
range 2
%
12.00
●
F27.09
Feedforward range 2
Feedforward range 2~ Feedforward
range 3
%
23.00
●
F27.10
Feedforward range 3
Feedforward range 3~ Feedforward
range 4
%
37.00
●
F27.11
Feedforward range 4
Feedforward range 4~ Feedforward
range 5
%
52.00
●
F27.12
Feedforward range 5
Feedforward range 5~100.00
%
72.00
●
F27.13
Soft start
incremental
0.00~50.00
%/s
0.60
●
F27.14
feedforward
increment 1
0.00~50.00
%/s
0.11
●
F27.15
feedforward
increment 2
0.00~50.00
%/s
0.30
●
F27.16
feedforward
increment 3
0.00~50.00
%/s
0.75
●
F27.17
feedforward
increment 4
0.00~50.00
%/s
1.55
●
F27.18
feedforward
increment 5
0.00~50.00
%/s
4.00
●
F27.19
feedforward
increment 6
0.00~50.00
%/s
11.00
●
F27.20
Material supply
disruptions control
way
Ones Place:Material supply disruptions
detection mode
0: Automatic detection
1: external signal
11211
〇