EM500 Open-Loop Vector Control Inverter User Manual
331
This mode can realize the Straight wire drawing machine mode function. After the
factory setting is restored, the parameters will be reverted to the Straight wire drawing
machine mode specific parameters
No
Explain
0:
Winding
mode
1:Unwindin
g mode
2:Wire
drawing
mode
3:Straight
wire
drawing
machine
mode
After setting F 16.00 = 3, and choose the macro, restore factory settings. The
application parameters are automatically set to the following default values.
The basic parameters (motor parameters need to be set manually, and do the
motor parameters of static autotuning)
F00.02
Command
Source
Options
1:
Terminal
Control
1: Terminal
Control
1: Terminal
Control
1: Terminal
Control
F00.03
Terminal
Control
Mode
Options
0:
Terminal
RUN for
running,
0: Terminal
RUN for
running,
0: Terminal
RUN for
running,
0: Terminal
RUN for
running,
F00.04
Main
Frequency
Source A
Options
1: AI1
given
0: Numeric
given
1: AI1 given
1: AI1 given
F00.05
Auxiliary
Frequency
Source B
Options
10:
Process
PID
10: Process
PID
10: Process
PID
F00.06
Frequency
Source
Options
6
Auxiliary
Frequency
Source B+
Feedforwa
rd
arithmetic
Winding
application
6
Auxiliary
Frequency
Source B+
Feedforwar
d
arithmetic
Winding
application
6
Auxiliary
Frequency
Source B+
Feedforwar
d arithmetic
Winding
application