EM500 Open-Loop Vector Control Inverter User Manual
305
F16.12=0: No Expansion Card
No expansion card means that the Inverter does not require a new function
provided by the interface card
F16.12=1: Clock Card
Clock card used in the water supply industry, it can provide timing water supply
function
F16.12=2: Air compressor interface Card
Air compressor interface Card used in Air compressor industry, it can be applied to
the provided by SINEE.
F16.12=3: Phase sequence phase detection card.
Phase sequence phase detection card is an independent function, not associated
with industry applications. After using the phase sequence phase interface card
The inverter can realize synchronous motor soft start after switching to power frequency.
1. After installing the optional card, you need to set F 16.12 to enable
the corresponding function. Please set F16.12 and then power off when
installed for the first time, then you can install the optional card.
2. Please replace the interface card after the LED light of the inverter
turns off
3.The phase sequence phase detection card is only applied to the
synchronous motor
7.18 F17 Group: Virtual I/O Function Parameter
EM500 inverter has 8 multi-function virtual input terminals (VX1 - VX8). Their
functions and use methods are basically the same as actual input terminals. In the
following, only the difference will be described. For the same functions and use methods
as that of actual input terminals, please refer to the descriptions of F02 Input Terminal