EM500 Open-Loop Vector Control Inverter User Manual
306
Function Parameters.
No.
Function
Range
Unit
Default
Type
F17.00
VX1 Virtual Input
Function
Same as the options of F02 group
numeric input terminals, please
refer to Table 7–2 Functions of
Numeric Multi-Function Input
Terminals
0
〇
F17.01
VX2 Virtual Input
Function
0
〇
F17.02
VX13Virtual Input
Function
0
〇
F17.03
VX4 Virtual Input
Function
0
〇
F17.04
VX5Virtual Input
Function
0
〇
F17.05
VX6 Virtual Input
Function
0
〇
F17.06
VX7 Virtual Input
Function
0
〇
F17.07
VX8 Virtual Input
Function
0
〇
F17.08
Positive/Negative
Logic of Virtual Input
D7
D6
D5
D4
D3
D2
D1
D0
000
00000
〇
VX8
VX7
VX6
VX5
VX4
VX3
VX2
VX1
0: Positive Logic, Enabled at
On/Disabled at Off
1: Negative Logic, Disabled at
On/Enabled at Off
F17.11
VX1 Effective Delay
Time
0.000 - 30.000
s
0.000
●
F17.12
VX1 Ineffective
Delay Time
0.000 - 30.000
s
0.000
●
F17.13
VX2 Effective Delay
Time
0.000 - 30.000
s
0.000
●
F17.14
VX2 Ineffective
Delay Time
0.000 - 30.000
s
0.000
●
F17.15
VX3 Effective Delay
Time
0.000 - 30.000
s
0.000
●
F17.16
VX3 Ineffective
Delay Time
0.000 - 30.000
s
0.000
●
F17.17
VX4 Effective Delay
Time
0.000 - 30.000
s
0.000
●
F17.18
VX4 Ineffective
0.000 - 30.000
s
0.000
●