EM500 Open-Loop Vector Control Inverter User Manual
288
(100.00 Hz)
Automatic Switching between
Acceleration and Deceleration
Time
Switching Frequency between
Acceleration Time 1 and
Acceleration Time 2
0.00 - Maximum
Frequency F00.16
Switching Frequency between
Acceleration Time 1 and
Acceleration Time 2
0.00 - Maximum
Frequency F00.16
If inverter runs at a common (other than PLC, PID, etc.) speed (other than torque,
etc.) of motor 1 and the acceleration and deceleration time terminals (19:
Acceleration/Deceleration Time Terminal 1, 19: Acceleration/Deceleration Time
Terminal 1) are disabled, inverter can complete the automatic switching between the two
terminals by setting F15.10 as 1. See Figure 7-34 for details.
Figure 7-34 Automatic Switching between Acceleration Time and Deceleration
Time
In acceleration, if output frequency is less than the value set through F15.11, then
the acceleration time 1 is the preset acceleration time, otherwise, the acceleration time 2
is present acceleration time
In deceleration, if output frequency is less than the value set through F15.12, then
the deceleration time 1 is the preset deceleration time, otherwise, the deceleration time 2