EM500 Open-Loop Vector Control Inverter User Manual
330
F26.19=2: Saturday and Sunday is invalid
Saturday and Sunday timing is given by the conventional date
No.
Function
Range
Unit
Default
Type
F26.18
T1 Start time
00.00~23.59
0.00
F26.19
T1 Start Pressure
F25.03~F25.02
%
0.1
F26.20
T2 Start time
T1~23.59
0.00
F26.21
T2 Start Pressure
F25.03~F25.02
%
0.1
F26.22
T3 Start time
T2~23.59
0.00
F26.23
T3 Start Pressure
F25.03~F25.02
%
0.1
F26.24
T4 Start time
T3~23.59
0.00
F26.25
T4 Start Pressure
F25.03~F25.02
%
0.1
F26.26
T5 Start time
T4~23.59
0.00
F26.27
T5 Start Pressure
F25.03~F25.02
%
0.1
F26.28
T6 Start time
T5~23.59
0.00
F26.29
T6 Start Pressure
F25.03~F25.02
%
0.1
The above parameters are used for multiple preset pressure water supply timing and
setting the corresponding pressure (effective on the conventional day).
7.23 F27 Winding rolling application
No.
Function
Range
Unit
Default
Type
F27.00
The application
of macro
0: Winding mode
1:Unwinding mode
2:Wire drawing mode
3:Straight wire drawing machine
mode
0
F27.00=0: Winding mode
This mode can realize the winding function. After the factory setting is restored, the
parameters will be reverted to the winding specific parameters
F27.00=1:Unwinding mode
This mode can realize the unwinding function. After the factory setting is restored, the
parameters will be reverted to the unwinding specific parameters
F27.00=2:Wire drawing mode
This mode can realize the wire drawing function. After the factory setting is restored, the
parameters will be reverted to the wire drawing specific parameters
F27.00=3:Straight wire drawing machine mode