EM500 Open-Loop Vector Control Inverter User Manual
140
4: Reverse Deceleration
5: Forward Constant Speed
6: Reverse Constant Speed
F19.05
Working Time at
Fault
h
0
×
F19.06
Last Fault Type
See F19.00 Parameter Description
0
×
F19.07
Output Frequency at
Fault
Hz
0.00
×
F19.08
Output Current at
Fault
A
0.00
×
F19.09
Bus Voltage at Fault
V
0
×
F19.10
Running Mode at
Fault
See F19.00 Parameter Description
0
×
F19.11
Working Time at
Fault
h
0
×
F19.12
Types of Last Two
Faults
See F19.04 Parameter Description
0
×
F19.13
Output Frequency at
Fault
Hz
0.00
×
F19.14
Output Current at
Fault
A
0.00
×
F19.15
Bus Voltage at Fault
V
0
×
F19.16
Running Mode at
Fault
See F19.04 Parameter Description
0
×
F19.17
Working Time at
Fault
h
0
×
F25
Application of water supply basic groups
F25.00
Run Mode Selection
0The basic mode of constant pressure
water supply
1Not Used
0
F25.01
Not Used
F25.02
Upper Limit
Pressure
F25.03~F09.03
%
/MP
a
100.0
F25.03
Lower Limit
Pressure
0.1~F25.02
%
/MP
a
0.1
F25.04
Overpressure alarm
pressure of pipe
networks
0.1~F09.03
%
/MP
a
100.0