EM500 Open-Loop Vector Control Inverter User Manual
359
hundreds place: Interface board
pressure
0: Curve 1
1: Curve 2
2: Curve 3
3: Curve 4
No.
Function
Range
Unit
Default
Type
F28.70
Loading and
unloading state
0: Unloading state
1: Loading status
2: Dormant state
0
×
It is used to check the working state of the current inverter
No.
Function
Range
Unit
Default
Type
F28.71
Time Error query
First place: Oil filter time
Second place: Oil separator time
Third place: Air filter time
Fourth place: Lubricating oil time
Fifth place: Grease time
From right to left
00000
×
After E51 fault occurs, you can check which mechanical part’s maintenance time is up
that it leads to the failure.
No.
Function
Range
Unit
Default
Type
F28.72
Stop delay
remaining time
0~60000
s
XXX
×
F28.73
Continuous
no-load running
time
0~60000
s
XXX
×
F28.74
Stop and restart
remaining time
0~60000
s
XXX
×
Used to view the frequency of start-up and stop delay time, can be displayed on the upper
computer.
No.
Function
Range
Unit
Default
Type
F28.75
The electricity
meter: MWh
0~65535
Mwh
XXX
×
F28.76
The electricity
meter: KWh
0~65535
KWh
XXX
×
This function code is used to record the power consumption, not saved in case of power