OnAir 3000 Digital Mixing Console
Networking 9-17
Document generated: 10.10.14
SW V6.0
•Professional IT switches (Cisco C2960G-8)
•No external routing device required for routing between OnAir Control
and Livewire network (done by Cisco C2960G-8)
•Cisco C2960G-8 has no fan
Disadvantages •Less flexible as manual IP address configuration required
•No redundant power supply available for Cisco C2960G-8
This solution is suitable for single consoles as well as for small OA3k /
Livewire networks with a few consoles and Livewire nodes.
The following picture shows a single OnAir3000 console with one D21m
Livewire card equipped, where the CORE and DESK containers have a
manually defined and fix IP address.
An additional Livewire node is connected to switch.
We recommend using the manageable switch Cisco WS-C2960G-8TC-L
Basic configuration files are provided by STUDER.
Customer switch configurations for this type of network topology are avail-
able for
•Cisco 2960-8 (Master)
Livewire Audio
Network 10.0.0.0
Management Console
Fix IP: 192.168.0.10
Subnet: 255.255.0.0
Gateway: 192.168.0.1
Core
Fix IP: 192.168.90.10
Subnet: 255.255.0.0
Gateway: 192.168.0.1
Desk
Fix IP: 192.168.90.100
Subnet: 255.255.0.0
Gateway: 192.168.0.1
Cisco C2960G-8 (Master/Gateway)
Switch IP VLan 1: 192.168.0.1 / 255.255.0.0
Switch IP VLan 2: 10.0.0.1 / 255.255.255.0
Axia Livewire xNode
Fix IP: 10.0.0.10
Subnet: 255.255.255.0
Gateway: 10.0.0.1
VLan 1 (Control)
VLan 2 (Livewire)
D21m Livewire card
LW1 Fix IP: 10.0.0.11
LW2 Fix IP: 10.0.0.12
Subnet: 255.255.255.0
Gateway: 10.0.0.1
VLan (Trunk)
As the picture on the following page shows, an additional Cisco C2960 switch
can be connected to a trunk port of the Master switch to expand the Control /
Livewire range. To expand the control network range only, a simple Layer-2
switch can be connected to a control port.