7.14.8 Parameter: CAM Prole Status (0x3805)
This object provides the current number of the selected CAM slave table (bits 0–3) and the used starting behavior. The
value 0 is allowed for the eld number of active CAM prole to indicate that no CAM is active. Bits 4–11 indicate if the CAM
prole is valid, meaning that it can be activated.
15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
CAM
error
buere
d only
end of
prole
reserve
d (0)
CAM prole validity number of active CAM prole
MSB LSB
Table 7.153 0x3805: CAM Prole Status
Bit Value Denition
0–3 0 No CAM slave table selected.
1–8 Activated CAM prole.
4 0 CAM prole 1 is invalid (and cannot be activated).
1 CAM prole 1 is valid.
5 0 CAM prole 2 is invalid (and cannot be activated).
1 CAM prole 2 is valid.
6 0 CAM prole 3 is invalid (and cannot be activated).
1 CAM prole 3 is valid.
7 0 CAM prole 4 is invalid (and cannot be activated).
1 CAM prole 4 is valid.
8 0 CAM prole 5 is invalid (and cannot be activated).
1 CAM prole 5 is valid.
9 0 CAM prole 6 is invalid (and cannot be activated).
1 CAM prole 6 is valid.
10 0 CAM prole 7 is invalid (and cannot be activated).
1 CAM prole 7 is valid.
11 0 CAM prole 8 is invalid (and cannot be activated).
1 CAM prole 8 is valid.
13 0 Axis is in the CAM or past the end of the prole.
1 End of prole is reached (only active for 1 cycle).
14 0 Only available if bit 15 = 1: General CAM error related to the active and the buered CAM prole.
1 Only available if bit 15 = 1: CAM error only related to the buered CAM, not the currently active CAM
prole.
15 0 No error.
1 Error occurred at CAM activation request; Remains at 1 until a new command is issued.
Table 7.154 Denition of Bits of the CAM Prole Status
Additional information for bit 13:
Bit 13 is a pulsed output signaling the cyclic end of the CAM prole. It is set every time that the end of the CAM prole is
reached. In reverse direction, bit 13 is shown at the end of the CAM prole (in this case, the rst point of the CAM prole).
This bit is only set for 1 eldbus cycle.
Additional information for bit 15:
Table 7.155 shows which situations lead to a CAM error (bit 15 of the CAM prole status object), and which lead to
command errors (signaled in the Statusword).
Servo Drive Parameter Descr... Programming Guide
MG36D102 Danfoss A/S © 01/2017 All rights reserved. 303
7 7

Table of Contents

Other manuals for Danfoss VLT series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss VLT series and is the answer not in the manual?

Danfoss VLT series Specifications

General IconGeneral
SeriesVLT
CategoryDC Drives
Output Voltage0-100% of input voltage
Protection FeaturesOvervoltage, Undervoltage, Overcurrent, Overtemperature, Short Circuit, Ground Fault
Communication InterfacesProfibus, CANopen
Enclosure RatingIP20, IP21, IP55, IP66
Cooling MethodForced Air Cooling, Convection Cooling
Control ModeSensorless Vector, Closed Loop Vector
Ambient Temperature-10°C to +50°C (14°F to 122°F)