Attribute Value
Sub-index 0x03
LCP Parameter number 12-02
Name IP mask
Data type UNSIGNED32
Access Read only
PDO mapping Yes
Value range 0x0000 0000–0xFFFF FFFF
Default value 0
Sub-index 0x04
LCP Parameter number 12-03
Name IP gateway
Data type UNSIGNED32
Access Read only
PDO mapping Yes
Value range 0x0000 0000–0xFFFF FFFF
Default value
Sub-index 0x08
LCP Parameter number 12-04
Name Mac address
Data type OCTET_STRING
Access Read only
PDO mapping Yes
Value range
Default value
Sub-index 0x0D
LCP Parameter number
Name Network topology
Data type UNSIGNED8
Access Read/write
PDO mapping No
Value range 0, 1
Default value 0
Table 8.24 0x400A: Communication Settings
8.30
Object 0x5020: Control Source
This object shows the control source for the SAB.
Value 0: Fieldbus is in control (writes are only
accepted from the eldbus).
Value 1: The LCP is in control (writes are only
accepted from the LCP).
Attribute Value
Index 0x5020
Description Control source
Object code Var
Data type UNSIGNED16
Sub-index 0x00
LCP parameter number
Access Read/write
Attribute Value
PDO mapping Yes
Value range 0 or 1
Default value 0
Table 8.25 Object 0x5020: Control Source
8.31 Object 0x5807: Total Running Time
The SAB has 2 counters for the running time:
Non-resettable counter (32 bits)
- Counts the time that the SAB has been
running in state Normal operation in
seconds.
Resettable counter
- Counts the time that the SAB has been
running in state Normal operation in
seconds.
- Can be reset by writing 0 to it and can
therefore be used to track service
intervals.
Attribute Value
Index 0x5807
Description Total running time
Object code Array
Sub-index 0x00
LCP parameter number
Description Number of entries
Access Read only
PDO mapping No
Value range 0x02
Default value 0x02
Sub-index 0x01
LCP parameter number 15-01
Description Total running time SAB
Access Read only
PDO mapping Yes
Object code Var
Data type UNSIGNED32
Sub-index 0x02
LCP parameter number 15-02
Description Total running time user
Access Read/write
PDO mapping Yes
Object code Var
Data type UNSIGNED32
Table 8.26 Object 0x5807: Total Running Time
SAB Parameter Description Programming Guide
MG36D102 Danfoss A/S © 01/2017 All rights reserved. 365
8 8

Table of Contents

Other manuals for Danfoss VLT series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss VLT series and is the answer not in the manual?

Danfoss VLT series Specifications

General IconGeneral
SeriesVLT
CategoryDC Drives
Output Voltage0-100% of input voltage
Protection FeaturesOvervoltage, Undervoltage, Overcurrent, Overtemperature, Short Circuit, Ground Fault
Communication InterfacesProfibus, CANopen
Enclosure RatingIP20, IP21, IP55, IP66
Cooling MethodForced Air Cooling, Convection Cooling
Control ModeSensorless Vector, Closed Loop Vector
Ambient Temperature-10°C to +50°C (14°F to 122°F)