7.22.9 Parameter 15-30: Error Code (0x603F)
This object provides the error code of the last error that occurred in the servo drive.
Attribute Value
Index 0x603F
LCP parameter number 15-30
Name Error code
Object code Var
Data type UNSIGNED16
Sub-index 0x00
Access Read only
PDO mapping Optional
Value range See chapter 9.2.1 Troubleshooting
Default value –
Table 7.256 0x603F: Error Code
7.22.10 Parameter 16-92: Warning Code (0x5FFE)
This object provides the warning code of the last warning that occurred in the servo drive.
Attribute Value
Index 0x5FFE
LCP parameter number 16-92
Name Warning code
Object code Var
Data type UNSIGNED16
Sub-index 0x00
Access Read only
PDO mapping Optional
Value range See chapter 9.2.2 Error Codes
Default value –
Table 7.257 0x5FFE: Warning Code
7.22.11 Parameter: Control Source (0x5020)
This object denes the current control source.
0 means that the device is controlled via eldbus (remote/PLC).
1 means that the device is controlled via LCP.
Attribute Value
Index 0x5020
LCP parameter number –
Name Control source
Object code Var
Data type UNSIGNED16
Sub-index 0x00
Access Read/write
PDO mapping Optional
Value range 0, 1
Servo Drive Parameter Descr...
VLT
®
Integrated Servo Drive ISD
®
510 System
352 Danfoss A/S © 01/2017 All rights reserved. MG36D102
77