7.22.2 Standstill Detection Objects
7.22.2.1 Parameter: Velocity Threshold (0x606F)
This object indicates the congured velocity threshold.
The value is given in user-dened velocity units.
Attribute Value
Index 0x606F
LCP parameter number
Name Velocity threshold
Object code Var
Data type UNSIGNED16
Sub-index 0x00
Access Read/write
PDO mapping Optional
Value range UNSIGNED16
Default value 6000 (corresponds to 10 RPM)
Table 7.243 0x606F: Velocity Threshold
7.22.2.2 Parameter: Velocity Threshold Time (0x6070)
This object indicates the congured velocity threshold time. The value is given in milliseconds.
Attribute Value
Index 0x6070
LCP parameter number
Name Velocity threshold time
Object code Var
Data type UNSIGNED16
Sub-index 0x00
Access Read/write
PDO mapping Optional
Value range UNSIGNED16
Default value 5
Table 7.244 0x6070: Velocity Threshold Time
Servo Drive Parameter Descr... Programming Guide
MG36D102 Danfoss A/S © 01/2017 All rights reserved. 345
7 7

Table of Contents

Other manuals for Danfoss VLT series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss VLT series and is the answer not in the manual?

Danfoss VLT series Specifications

General IconGeneral
SeriesVLT
CategoryDC Drives
Output Voltage0-100% of input voltage
Protection FeaturesOvervoltage, Undervoltage, Overcurrent, Overtemperature, Short Circuit, Ground Fault
Communication InterfacesProfibus, CANopen
Enclosure RatingIP20, IP21, IP55, IP66
Cooling MethodForced Air Cooling, Convection Cooling
Control ModeSensorless Vector, Closed Loop Vector
Ambient Temperature-10°C to +50°C (14°F to 122°F)