Attribute Value
Data type INTEGER32
Sub-index 0x00
Description Value of highest sub-index
Access Read only
PDO mapping No
Default value 0x02
Sub-index 0x01
LCP parameter number –
Description First position of touch probe 1
Access Read/write
Data type INTEGER32
PDO mapping Optional
Value range INTEGER32
Default value –
Sub-index 0x02
LCP parameter number –
Description First position of touch probe 2
Access Read/write
Data type INTEGER32
PDO mapping Optional
Value range INTEGER32
Default value –
Table 7.193 0x3853: First Position
7.18.9 Parameter: Last Position (0x3854)
This object denes the end position of the window. The value is given in user-dened position units.
Attribute Value
Index 0x3854
Name Last position
Object code Array
Data type INTEGER32
Sub-index 0x00
Description Value of highest sub-index
Access Read only
PDO mapping No
Default value 0x02
Sub-index 0x01
LCP parameter number –
Description Last position of touch probe 1
Access Read/write
Data type INTEGER32
PDO mapping Optional
Value range INTEGER32
Default value –
Sub-index 0x02
LCP parameter number –
Servo Drive Parameter Descr... Programming Guide
MG36D102 Danfoss A/S © 01/2017 All rights reserved. 323