JUNOS Internet Software Network Operations Guide: Hardware
82 ! Using the Basic Monitoring Method
SIB A spare SIB is missing. Insert a spare SIB into
an empty slot.
Yellow
An SIB failed. Replace the failed SIB. Yellow
A spare SIB failed. Replace the failed SIB. Yellow
A SIB has an out-of-range or
invalid temperature reading.
Replace the failed SIB. Yellow
An SIB is missing. Insert an SIB into empty
slot.
Red
An SIB failed. Replace the failed SIB. Red
SPMB A local SPMB is offline. Reset the Control Board.
If this fails, replace the
Control Board.
Red
Temperature The chassis temperature
exceeded 55 degrees, the fans
turned on to full speed, and
one or more fans have failed.
! Check the room
temperature.
! Check the air filter
and replace it.
! Check the air flow.
! Check the fan.
Yellow
The chassis temperature
exceeded 65 degrees C and
the fans have been turned on
to full speed.
! Check the room
temperature.
! Check the air filter
and replace it.
! Check the air flow.
! Check the fan.
Yellow
The chassis temperature
exceeded 65 degrees C and a
fan failed. If this condition
persists for more than 4
minutes, the router shuts
down.
! Check the room
temperature.
! Check the air filter
and replace it.
! Check the air flow.
! Check the fan.
Red
Chassis temperature exceeded
75 degrees C. If this condition
persists for more than 4
minutes, the router shuts
down.
! Check the room
temperature.
! Check the air filter
and replace it.
! Check the air flow.
! Check the fan.
Red
The temperature sensor failed. For technical support,
open a support case
using the Case Manager
link at
http://www.juniper.net
/support/
or call
1-888-314-JTAC (within
the United States) or
1-408-745-9500 (outside
the United States).
Red
Chassis
Component
Alarm Condition Remedy
Alarm
Severity

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Juniper JUNOS - NETWORK OPERATION GUIDE REV1 and is the answer not in the manual?

Juniper JUNOS - NETWORK OPERATION GUIDE REV1 Specifications

General IconGeneral
BrandJuniper
ModelJUNOS - NETWORK OPERATION GUIDE REV1
CategorySoftware
LanguageEnglish

Related product manuals