6.4 Part Names and Functions
6.4.2 Part names and functions of the Q06CCPU-V(-B)
6 - 35
1
OVERVIEW
2
SYSTEM
CONFIGURATION
3
SPECIFICATIONS
4
FUNCTIONS
5
ACCESS VIA NETWORK
MODULES
6
PREPARATORY
PROCEDURES AND
SETTING
7
I/O NUMBER
ASSIGNMENT
8
MEMORIES AND FILES
(2) RUN/STOP/MODE switch operation
* 1 Operations such as forced output (Y) and buffer memory writing can be executed from the
<<Module monitoring>> tab of C Controller setting utility.
Figure 6.29 The RUN/STOP/MODE switch
Table 6.14 RUN/STOP/MODE switch operation
Position Operation
RUN
In normal operation mode
The C Controller module is operating.
(Output (Y) from a user program and writing to the buffer memory are enabled.)
In hardware self-
diagnostic operation
mode
For the hardware self-diagnostic function, refer to the following.
Page 16-84, Section 16.5.2
STOP
The operation of the C Controller module is stopped.
*1
Switching from RUN to STOP turns off all outputs (Y).
(Output (Y) from a user program and writing to the buffer memory are disabled.)
MODE
Used for the hardware self-diagnostic function. (
Page 16-84, Section 16.5.2)