APPX - 32
Appendix 9 Connection with GX Works2/GX Developer
Appendix 9.1 When accessing another CPU of a multiple CPU system
APPENDICES
(b) Ethernet connection
To access another CPU module of a multiple CPU system from the C Controller
module via Ethernet, follow the procedure below.
• To connect GX Developer to the C Controller module via Ethernet, built-in
Ethernet port open settings need to be configured on the <<System
settings>> tab of the C Controller setting utility.
For details, refer to the following.
C Controller Module User's Manual (Utility Operation,
Programming)
• When connected to GX Developer through Ethernet, the C Controller
module cannot access the following CPU modules.
Connect them with a USB cable. ( Page App-30, Appendix 9.1 (2)
(a))
1) [Online] Select [Transfer setup].
• Q00CPU, Q01CPU
• Q00UCPU, Q01UCPU, Q02UCPU