Chapter 3: FRU Removal and Replacement Procedures
Replacing Node Expansion Cards
Quantum DXi6900 G1 User’s Guide 131
d If applicable, connect any cables to the expansion card.
3 Re-install 6 Gb SAS card in Slot 6:
a Holding the card by its edges, position the card so that the
connector on the expansion card aligns with the expansion card
connector on the riser (see
Figure 74).
b Insert the card-edge connector firmly into the expansion card
connector until the card is fully seated.
c To install a full length card, use the supports provided on the
cooling shroud.
d Replace the expansion card latch.
4 Close the Node cover (see Opening and Closing the Node on
page 78).
5 Reattach all Fibre Channel and Node cables (see Appendix A,
Cabling Diagrams).
Note: Reconnect the labeled PTT cables to the appropriate port
(F4 or F5). Swapping from 8 Gb to 16 Gb Fibre Channel
reduces the number of available ports from 6 to 4. If one of
the reduced ports was a PTT port, you will need to
reconfigure a new port for PTT.
6 Turn on the system (see Turning On and Shutting Down the System
on page 23).
Note: If a Fibre Channel switch with supported World Wide Port
Name (WWPN) zoning is being used, rezone using the new
WWPN.
7 Run Factory Detect Hardware from the Service Menu to detect the
new hardware (see
Factory Detect Hardware on page 44).
8 Log on to the remote management console as the service user (see
Accessing Remote Management on page 25).
9 Navigate to Configuration > VTL > Remote Host Access >
Remote Host Mapping.
10 Under Remote Host Mapping & Groups, create new groups and
remap to the appropriate target ports.