Chapter 2  Installation and Configuration
Setting SCSI ID
32 SuperLoader User’s Guide
To configure the SuperLoader, you must verify the setup of the following:
• SCSI ID(s). For the SuperLoader DLT and SuperLoader SDLT, there is 
a single SCSI ID. For the SuperLoader LTO, there are separate SCSI 
IDs for the drive and the loader.
• Magazine(s)
• Ethernet IP address (if you are not using DHCP)
• SNMP server IP address—only if SNMP is being used
• Time server IP address (or the time zone, date, and time, if 
configuring manually)—only if a time server is being used
• Control mode
• Security option
Setting SCSI ID 2
Each SCSI device attached to a server or workstation must have a unique 
SCSI ID. For the SuperLoader DLT, you need one SCSI ID for the 
SuperLoader. For SuperLoader LTO models, you need to set up separate 
SCSI IDs for the tape drive and the SuperLoader.
Check the IDs on all other SCSI devices that are on the SCSI bus, 
including the SCSI host adapter, and select unused SCSI IDs for the 
SuperLoader robotics (all models) and drive (SDLT 600 drive and LTO 
drive only). The factory default SCSI IDs for the SuperLoader robotics, 
SDLT 600 drive, and LTO drive are 04 and 05 respectively, but you can 
select any unused number between 00 and 15. If the SuperLoader factory 
default SCSI IDs are being used by other devices on the SCSI bus, you 
need to change these SCSI IDs to avoid conflicts.
To Set the SCSI ID: 2
1 If the main menu is not already visible, press 
Enter.
2 On the main menu, scroll to 
Configuration and press Enter.