Chapter 4  SuperLoader Operation
Configurations Page
114 SuperLoader User’s Guide
The element addresses vary depending on which magazine is 
configured. If 
Left or Right is selected, and both magazines are 
physically installed, the front panel and On-board Remote Manager 
will allow user access to the other magazine, but the SCSI host will 
not have access.
To set the Magazine option: 4
1 On the main menu, scroll to 
Configuration, then press Enter.
2 On the 
Configuration menu, scroll to Magazines, then press Enter. The 
Magazine options display. A check mark appears after the currently 
enabled mode.
3 Do one of the following:
• To leave the 
Magazine mode unchanged, press Escape.
•To change the 
Magazine configuration, scroll to the setting you 
want for the SuperLoader, and then press 
Enter. These settings 
are 
Both, Right, and Left.
The message 
This will require a power cycle and an ISV configuration 
change. Enter To Continue
 is displayed.
• To leave the setting unchanged, press
 Escape.
• To continue with the change, press 
Enter. The message Please 
power cycle the tape autoloader and reconfigure the ISV app.
 displays.
Set the System 
Time 4
The system time is displayed by the On-board Remote Manager and it is 
used internally when logging events and errors (see Time Display
 on 
page 104).