Chapter 6  Diagnostics
Diagnostic Tests
224 SuperLoader User’s Guide
To Enter an Administrator Password: 6
1 On the main menu, scroll to 
Commands, then press Enter.
2 On the Command submenu, scroll to 
Enter Password, then press 
Enter.
3 On the Enter Password submenu, scroll to 
Administrator, then press 
Enter.
The Login screen appears with a row of asterisks. A textbox appears 
above the first asterisk.
4 In the textbox, scroll to the first number of the password, then press 
Enter. The textbox above the asterisk disappears and another textbox 
appears above the next asterisk.
5 Repeat step 4
 to enter the remaining numbers of your password.
When you have finished entering your password, the LCD displays 
Submit Password below the asterisks.
6 Press 
Enter to submit your password. You return to the Enter 
Password
 submenu.
Stop a Diagnostic 
Test 6
At times you may need to stop a diagnostic test while it is in progress. 
Certain diagnostic tests even require you to stop them or they run 
continuously. To stop a diagnostic test while it is running, use the 
Halt 
Test
 function. When you select Halt Test, any picker or magazine 
functions complete and then the Diagnostic test is stopped.
To Perform a Halt Test from the Front Panel: 6
1 While the diagnostic test that you wish to stop is running, press 
Escape. The Diagnostic submenu appears.
2 On the submenu, scroll to 
Halt Test, then press Enter. User Abort 
appears.
3 Press 
Enter to return to the Diagnostics submenu. Refer to On-board 
Remote Management for any test results.
Note: Press 
Escape to backspace to a previous textbox, if 
necessary.