CALCulate:BTOoth Subsystem (BLUETOOTH, K8) R&S FSL
1300.2519.12 6.352 E-11
Parameter
MINimum | MAXimum | AVERage
Example
For the first steps refer to "Example: Adapting the settings to the characteristics of the DUT" on
p
age 6.334.
CONF:BTO:MEAS RTP
Activates the Relative Transmit Power measurement.
CONF:BTO:SWE:COUN 10
Initiates the sweep counter with 10.
INIT;*WAI
Starts the measurement with synchronization.
CALC:BTO:RTP:RAT? MIN
Queries the minimum value.
Characteristics
RST value:
SCPI: device–specific
Mode
BT
CALCulate<1|2>:BTOoth:STATus?
This command queries the status of a preceding measurement.
Results: 0: PASS, 1: FAIL
The numeric suffixes <1|2> are irrelevant for this command.
Note: This command is only available, if a measurement was started via
INITiate<1|2>[:IMMediate] before and if this measurement is completed. With a
missing or incomplete measurement the command will cause a query error.
Example
INST:SEL BTO
Activates the Bluetooth Measurements option
INIT:CONT OFF
Selects single sweep operation
CONF:BTO:MEAS OPOW
Activates Output Power measurement
INIT;*WAI
Starts the measurement with synchronization
CALC:BTO:STAT?
Queries the status
Characteristics
RST value:
SCPI: device–specific