CALCulate Subsystem (CATV, K20) R&S FSL
1300.2519.12 6.454 E-11
Characteristics
RST value:
SCPI: device–specific
Mode
CATV
CALCulate:DTV:LIMit:RESult:IMBalance:UPPer?
This command performs an upper limit check for the I/Q amplitude imbalance value in the
Modulation Errors measurement.
This command is a query and therefore has no *RST value.
Example
CALC:DTV:LIM:IMB:UPP 10
Sets the upper limit for the I/Q amplitude imbalance value to 10%.
INIT;*WAI
Starts a new measurement and waits for the sweep end.
CALC:DTV:LIM:RES:IMB:UPP?
Performs an upper limit check for the I/Q amplitude imbalance value.
Characteristics
RST value:
SCPI: device–specific
Mode
CATV
CALCulate:DTV:LIMit:RESult:MERPeak:LOWer?
This command performs a lower limit check for the modulation error rate peak in the Overview
measurement.
This command is a query and therefore has no *RST value.
Example
CALC:DTV:LIM:MERP:LOW 20
Sets the lower limit for the modulation error rate peak to 20 dB.
INIT;*WAI
Starts a new measurement and waits for the sweep end.
CALC:DTV:LIM:RES:MERP:LOW?
Performs a lower limit check for the modulation error rate peak.