CONFigure Subsystem (CATV, K20) R&S FSL
1300.2519.12 6.470 E-11
C
ONFigure:ATV:CSO:MEASurement
This command configures a new carrier or noise measurement with the next sweep for the
Carrier–to–Second Order Beat Ratio measurement.
Parameter
CARRier | NOISe
Example
CONF:ATV:MEAS CSO
Configures the analog TV Carrier–to–Second Order Beat Ratio measurement.
ATV:CSO:MEAS:MODE OSER
Sets the Off–Service measurement method.
CONF:ATV:CSO:MEAS CARR
Configures a new carrier measurement with the next sweep.
INIT;*OPC
Starts the new noise measurement.
Characteristics
RST value: CARRier
SCPI: device–specific
Mode
CATV
CONFigure:ATV:CTB:MEASurement
This command configures a new carrier or noise measurement with the next sweep for the
Carrier–to–Composite Triple Beat Ratio measurement.
Parameter
CARRier | NOISe
Example
CONF:ATV:MEAS CTB
Configures the analog TV Carrier–to–Composite Triple Beat Ratio measurement.
ATV:CTB:MEAS:MODE OSER
Sets the Off–Service measurement method.
CONF:ATV:CTB:MEAS CARR
Configures a new carrier measurement with the next sweep.
INIT;*OPC
Starts the new noise measurement.
Characteristics
RST value: CARRier
SCPI: device–specific
Mode
CATV